gaoluyang
2026-08-06 377c0a70c094d024aeb0bb94f4b791c6d5530c1e
src/views/safeProduction/emergencyPlanReview/index.vue
@@ -1,6 +1,6 @@
<template>
  <div class="app-container">
    <div class="search_form">
    <div class="search_form mb20">
      <div>
        <span class="search_title">应急预案名称:</span>
        <el-input v-model="searchForm.planName"
@@ -30,7 +30,7 @@
                   @click="openForm('add')">新增应急预案</el-button>
        <el-button type="danger"
                   plain
                   @click="handleDelete">删除</el-button>
                   @click="handleDelete" v-hasPermi="['safeProduction:emergencyPlanReview:remove']">删除</el-button>
      </div>
    </div>
    <div class="table_list">
@@ -52,17 +52,18 @@
      <el-form ref="formRef"
               :model="form"
               :rules="rules"
               label-width="120px">
               label-position="top"
               label-width="150px">
        <el-row :gutter="20">
          <el-col :span="12">
            <el-form-item label="应急预案编码"
            <el-form-item label="应急预案编码:"
                          prop="planCode">
              <el-input v-model="form.planCode"
                        placeholder="请输入应急预案编码" />
            </el-form-item>
          </el-col>
          <el-col :span="12">
            <el-form-item label="应急预案名称"
            <el-form-item label="应急预案名称:"
                          prop="planName">
              <el-input v-model="form.planName"
                        placeholder="请输入应急预案名称" />
@@ -85,7 +86,7 @@
          <el-col :span="12">
            <el-form-item label="核心责任人:"
                          prop="coreResponsorUserId">
              <el-select v-model="form.coreResponsorUserId"
              <el-select filterable v-model="form.coreResponsorUserId"
                         placeholder="请选择"
                         @change="handleChange"
                         clearable>
@@ -99,7 +100,7 @@
        </el-row>
        <el-row :gutter="20">
          <el-col :span="12">
            <el-form-item label="预案类型"
            <el-form-item label="预案类型:"
                          prop="planType">
              <el-select v-model="form.planType"
                         placeholder="请选择预案类型"
@@ -112,14 +113,14 @@
            </el-form-item>
          </el-col>
          <el-col :span="12">
            <el-form-item label="备注"
            <el-form-item label="备注:"
                          prop="remark">
              <el-input v-model="form.remark"
                        placeholder="请输入备注" />
            </el-form-item>
          </el-col>
        </el-row>
        <el-form-item label="适用范围"
        <el-form-item label="适用范围:"
                      prop="applyScope">
          <el-checkbox-group v-model="form.applyScope">
            <el-checkbox label="all">全体员工</el-checkbox>
@@ -129,7 +130,7 @@
            <el-checkbox label="tech">技术部门</el-checkbox>
          </el-checkbox-group>
        </el-form-item>
        <el-form-item label="应急处置步骤"
        <el-form-item label="应急处置步骤:"
                      prop="execSteps">
          <div class="exec-steps-container"
               style="width:100%">
@@ -144,7 +145,7 @@
                  <el-button type="danger"
                             size="small"
                             @click="removeExecStep(index)"
                             style="margin-left: 10px">删除</el-button>
                             style="margin-left: 10px" v-hasPermi="['safeProduction:emergencyPlanReview:remove']">删除</el-button>
                </div>
                <div style="margin-top: 5px;width: 100%;">
                  <el-input v-model="step.description"
@@ -164,9 +165,9 @@
      </el-form>
      <template #footer>
        <span class="dialog-footer">
          <el-button @click="dialogVisible = false">取消</el-button>
          <el-button type="primary"
                     @click="submitForm">确定</el-button>
          <el-button @click="dialogVisible = false">取消</el-button>
        </span>
      </template>
    </el-dialog>
@@ -192,7 +193,7 @@
            {{ currentKnowledge.coreResponsorUserName }}
          </el-descriptions-item>
          <el-descriptions-item label="预案类型">
            <el-tag type="warning"> {{ currentKnowledge.planType }}</el-tag>
            <el-tag type="warning"> {{ emergencyPlanTypeLabel(currentKnowledge.planType) }}</el-tag>
          </el-descriptions-item>
          <el-descriptions-item label="备注">
            {{ currentKnowledge.remark }}
@@ -216,7 +217,7 @@
              <div v-for="(step, index) in JSON.parse(currentKnowledge.execSteps)"
                   :key="index"
                   class="exec-step-view">
                <span class="step-number">{{ index + 1 }}.</span>
                <!-- <span class="step-number">{{ index + 1 }}.</span> -->
                <span class="step-title">{{ step.step }}:</span>
                <span>{{ step.description }}</span>
              </div>
@@ -352,6 +353,9 @@
      label: "预案类型",
      prop: "planType",
      showOverflowTooltip: true,
      formatData: params => {
        return emergencyPlanTypeLabel(params);
      },
    },
    {
      label: "备注",
@@ -441,7 +445,7 @@
      .then(res => {
        tableLoading.value = false;
        tableData.value = res.data.records;
        page.total = res.data.total;
        page.value.total = res.data.total;
      })
      .catch(err => {
        tableLoading.value = false;
@@ -452,7 +456,7 @@
  const pagination = obj => {
    page.value.current = obj.page;
    page.value.size = obj.limit;
    handleQuery();
    getList();
  };
  // 选择变化处理
@@ -569,20 +573,17 @@
    };
    return timeMap[efficiency] || "未知";
  };
  const emergencyPlanTypeOptions = computed(() => [
    {
      value: "预防性应急预案",
      label: "预防性应急预案",
    },
    {
      value: "应急处理预案",
      label: "应急处理预案",
    },
    {
      value: "恢复性应急预案",
      label: "恢复性应急预案",
    },
  ]);
  const { proxy } = getCurrentInstance();
  const { emergency_plan_type } = proxy.useDict("emergency_plan_type");
  const emergencyPlanTypeOptions = computed(
    () => emergency_plan_type?.value || []
  );
  const emergencyPlanTypeLabel = val => {
    const item = emergencyPlanTypeOptions.value.find(
      i => String(i.value) === String(val)
    );
    return item ? item.label : val;
  };
  // 提交应急预案表单
  const submitForm = async () => {
    try {
@@ -664,8 +665,6 @@
  };
  // 导出
  const { proxy } = getCurrentInstance();
  const { knowledge_type } = proxy.useDict("knowledge_type");
  // 字典工具
  const knowledgeTypeOptions = computed(() => knowledge_type?.value || []);
@@ -766,45 +765,83 @@
  .exec-steps-container {
    border: 1px solid #e4e7ed;
    border-radius: 4px;
    padding: 15px;
    border-radius: 8px;
    padding: 20px;
    background-color: #f9fafc;
    margin-top: 10px;
  }
  .exec-step-item {
    margin-bottom: 10px;
    padding: 10px;
    margin-bottom: 12px;
    padding: 12px;
    background-color: #ffffff;
    border: 1px solid #e4e7ed;
    border-radius: 4px;
    border-radius: 6px;
    transition: all 0.3s ease;
  }
  .exec-step-item:hover {
    box-shadow: 0 2px 12px 0 rgba(0, 0, 0, 0.1);
    border-color: #c6e2ff;
  }
  .step-header {
    display: flex;
    align-items: flex-start;
    flex-direction: column;
    gap: 8px;
  }
  .exec-step-view {
    margin-bottom: 8px;
    padding-left: 20px;
    margin-bottom: 16px;
    padding-left: 24px;
    position: relative;
    line-height: 1.6;
  }
  .exec-step-view::before {
    content: "";
    position: absolute;
    left: 10px;
    top: 20px;
    bottom: -16px;
    width: 2px;
    background-color: #eaeaea;
  }
  .exec-step-view:last-child::before {
    display: none;
  }
  .step-number {
    position: absolute;
    left: 0;
    top: 0;
    width: 20px;
    height: 20px;
    line-height: 20px;
    text-align: center;
    font-weight: bold;
    color: #409eff;
    color: #ffffff;
    background-color: #409eff;
    border-radius: 50%;
    font-size: 12px;
    z-index: 1;
  }
  .step-title {
    font-weight: bold;
    margin-right: 5px;
    font-weight: 600;
    margin-right: 8px;
    color: #395a9c;
  }
  .no-data {
    color: #909399;
    font-style: italic;
    text-align: center;
    padding: 20px;
    background-color: #f8f9fa;
    border-radius: 4px;
    margin-top: 10px;
  }
</style>