From 6735ee5fec84b96a2484a784e37d4cefb4f7c34c Mon Sep 17 00:00:00 2001
From: gongchunyi <deslre0381@gmail.com>
Date: 星期五, 14 八月 2026 10:32:56 +0800
Subject: [PATCH] fix: 去除小数限制
---
src/views/safeProduction/emergencyPlanReview/index.vue | 214 +++++++++++++++++++++++++++++++++++++----------------
1 files changed, 150 insertions(+), 64 deletions(-)
diff --git a/src/views/safeProduction/emergencyPlanReview/index.vue b/src/views/safeProduction/emergencyPlanReview/index.vue
index 07bf56e..bf06b32 100644
--- a/src/views/safeProduction/emergencyPlanReview/index.vue
+++ b/src/views/safeProduction/emergencyPlanReview/index.vue
@@ -1,6 +1,6 @@
<template>
<div class="app-container">
- <div class="search_form">
+ <div class="search_form mb20">
<div>
<span class="search_title">搴旀�ラ妗堝悕绉帮細</span>
<el-input v-model="searchForm.planName"
@@ -52,17 +52,18 @@
<el-form ref="formRef"
:model="form"
:rules="rules"
- label-width="120px">
+ label-position="top"
+ label-width="150px">
<el-row :gutter="20">
<el-col :span="12">
- <el-form-item label="搴旀�ラ妗堢紪鐮�"
+ <el-form-item label="搴旀�ラ妗堢紪鐮侊細"
prop="planCode">
<el-input v-model="form.planCode"
placeholder="璇疯緭鍏ュ簲鎬ラ妗堢紪鐮�" />
</el-form-item>
</el-col>
<el-col :span="12">
- <el-form-item label="搴旀�ラ妗堝悕绉�"
+ <el-form-item label="搴旀�ラ妗堝悕绉帮細"
prop="planName">
<el-input v-model="form.planName"
placeholder="璇疯緭鍏ュ簲鎬ラ妗堝悕绉�" />
@@ -99,7 +100,7 @@
</el-row>
<el-row :gutter="20">
<el-col :span="12">
- <el-form-item label="棰勬绫诲瀷"
+ <el-form-item label="棰勬绫诲瀷锛�"
prop="planType">
<el-select v-model="form.planType"
placeholder="璇烽�夋嫨棰勬绫诲瀷"
@@ -112,24 +113,25 @@
</el-form-item>
</el-col>
<el-col :span="12">
- <el-form-item label="澶囨敞"
+ <el-form-item label="澶囨敞锛�"
prop="remark">
<el-input v-model="form.remark"
placeholder="璇疯緭鍏ュ娉�" />
</el-form-item>
</el-col>
</el-row>
- <el-form-item label="閫傜敤鑼冨洿"
+ <el-form-item label="閫傜敤鑼冨洿锛�"
prop="applyScope">
- <el-checkbox-group v-model="form.applyScope">
- <el-checkbox label="all">鍏ㄤ綋鍛樺伐</el-checkbox>
- <el-checkbox label="manager">绠$悊灞�</el-checkbox>
- <el-checkbox label="hr">浜轰簨閮ㄩ棬</el-checkbox>
- <el-checkbox label="finance">璐㈠姟閮ㄩ棬</el-checkbox>
- <el-checkbox label="tech">鎶�鏈儴闂�</el-checkbox>
+ <el-checkbox-group v-model="form.applyScope"
+ class="apply-scope-checkbox-group">
+ <el-checkbox v-for="dept in applyScopeOptions"
+ :key="dept.deptId"
+ :value="String(dept.deptId)">
+ {{ dept.deptName }}
+ </el-checkbox>
</el-checkbox-group>
</el-form-item>
- <el-form-item label="搴旀�ュ缃楠�"
+ <el-form-item label="搴旀�ュ缃楠わ細"
prop="execSteps">
<div class="exec-steps-container"
style="width:100%">
@@ -164,9 +166,9 @@
</el-form>
<template #footer>
<span class="dialog-footer">
- <el-button @click="dialogVisible = false">鍙栨秷</el-button>
<el-button type="primary"
@click="submitForm">纭畾</el-button>
+ <el-button @click="dialogVisible = false">鍙栨秷</el-button>
</span>
</template>
</el-dialog>
@@ -192,7 +194,7 @@
{{ currentKnowledge.coreResponsorUserName }}
</el-descriptions-item>
<el-descriptions-item label="棰勬绫诲瀷">
- <el-tag type="warning"> {{ currentKnowledge.planType }}</el-tag>
+ <el-tag type="warning"> {{ emergencyPlanTypeLabel(currentKnowledge.planType) }}</el-tag>
</el-descriptions-item>
<el-descriptions-item label="澶囨敞">
{{ currentKnowledge.remark }}
@@ -201,11 +203,11 @@
<div class="detail-section">
<h4>閫傜敤鑼冨洿</h4>
<div class="key-points">
- <el-tag v-for="(point, index) in currentKnowledge.applyScope.split(',')"
- :key="index"
+ <el-tag v-for="(scope, index) in getApplyScopeTags(currentKnowledge)"
+ :key="`${scope.value}-${index}`"
type="primary"
style="margin-right: 8px; margin-bottom: 8px;">
- {{ getApplyScopeLabel(point.trim()) }}
+ {{ scope.label }}
</el-tag>
</div>
</div>
@@ -216,7 +218,7 @@
<div v-for="(step, index) in JSON.parse(currentKnowledge.execSteps)"
:key="index"
class="exec-step-view">
- <span class="step-number">{{ index + 1 }}.</span>
+ <!-- <span class="step-number">{{ index + 1 }}.</span> -->
<span class="step-title">{{ step.step }}锛�</span>
<span>{{ step.description }}</span>
</div>
@@ -249,6 +251,7 @@
import { ElMessage, ElMessageBox } from "element-plus";
import PIMTable from "@/components/PIMTable/PIMTable.vue";
import { userListNoPage } from "@/api/system/user.js";
+ import { listDept } from "@/api/system/dept.js";
import {
safeContingencyPlanListPage,
safeContingencyPlanAdd,
@@ -325,37 +328,59 @@
// 琛ㄥ崟寮曠敤
const formRef = ref();
const execStepsList = ref([]);
+ const applyScopeOptions = ref([]);
+ const applyScopeNameMap = computed(() => {
+ return applyScopeOptions.value.reduce((map, dept) => {
+ map[String(dept.deptId)] = dept.deptName;
+ return map;
+ }, {});
+ });
// 琛ㄦ牸鍒楅厤缃�
const tableColumn = ref([
{
label: "搴旀�ラ妗堢紪鐮�",
prop: "planCode",
+ minWidth: 200,
+ align: "center",
showOverflowTooltip: true,
},
{
label: "搴旀�ラ妗堝悕绉�",
prop: "planName",
+ minWidth: 240,
+ align: "center",
showOverflowTooltip: true,
},
{
label: "鍙戝竷鐢熸晥鏃堕棿",
prop: "publishTime",
+ minWidth: 160,
+ align: "center",
showOverflowTooltip: true,
},
{
label: "鏍稿績璐d换浜�",
prop: "coreResponsorUserName",
+ minWidth: 140,
+ align: "center",
showOverflowTooltip: true,
},
{
label: "棰勬绫诲瀷",
prop: "planType",
+ minWidth: 160,
+ align: "center",
showOverflowTooltip: true,
+ formatData: params => {
+ return emergencyPlanTypeLabel(params);
+ },
},
{
label: "澶囨敞",
prop: "remark",
+ minWidth: 220,
+ align: "center",
showOverflowTooltip: true,
},
{
@@ -363,7 +388,7 @@
label: "鎿嶄綔",
align: "center",
fixed: "right",
- width: 200,
+ width: 120,
operation: [
{
name: "缂栬緫",
@@ -388,6 +413,7 @@
userListNoPage().then(res => {
userList.value = res.data;
});
+ loadApplyScopeOptions();
getList();
startAutoRefresh();
});
@@ -422,6 +448,22 @@
execStepsList.value = [];
}
};
+
+ const loadApplyScopeOptions = () => {
+ listDept({ status: "0" }).then(res => {
+ applyScopeOptions.value = res.data || [];
+ });
+ };
+
+ const parseApplyScope = scope => {
+ if (Array.isArray(scope)) {
+ return scope.map(item => String(item)).filter(Boolean);
+ }
+ return String(scope || "")
+ .split(",")
+ .map(item => item.trim())
+ .filter(Boolean);
+ };
// 寮�濮嬭嚜鍔ㄥ埛鏂�
const startAutoRefresh = () => {
setInterval(() => {
@@ -441,7 +483,7 @@
.then(res => {
tableLoading.value = false;
tableData.value = res.data.records;
- page.total = res.data.total;
+ page.value.total = res.data.total;
})
.catch(err => {
tableLoading.value = false;
@@ -452,7 +494,7 @@
const pagination = obj => {
page.value.current = obj.page;
page.value.size = obj.limit;
- handleQuery();
+ getList();
};
// 閫夋嫨鍙樺寲澶勭悊
@@ -467,6 +509,7 @@
dialogTitle.value = "鏂板搴旀�ラ妗�";
// 閲嶇疆琛ㄥ崟
Object.assign(form.value, {
+ id: undefined,
planCode: "", // 棰勬缂栧彿
applyScope: [], // 閫傜敤鑼冨洿
planType: "", // 棰勬绫诲瀷
@@ -483,7 +526,7 @@
Object.assign(form.value, {
id: row.id,
planCode: row.planCode, // 棰勬缂栧彿
- applyScope: row.applyScope ? row.applyScope.split(",") : [], // 閫傜敤鑼冨洿
+ applyScope: parseApplyScope(row.applyScope), // 閫傜敤鑼冨洿
planType: row.planType, // 棰勬绫诲瀷
planName: row.planName, // 棰勬鍚嶇О
publishTime: row.publishTime, // 鍙戝竷鏃堕棿
@@ -503,14 +546,13 @@
viewDialogVisible.value = true;
};
const getApplyScopeLabel = scope => {
- const scopeMap = {
- all: "鍏ㄤ綋鍛樺伐",
- manager: "绠$悊灞�",
- hr: "浜轰簨閮ㄩ棬",
- finance: "璐㈠姟閮ㄩ棬",
- tech: "鎶�鏈儴闂�",
- };
- return scopeMap[scope] || scope;
+ return applyScopeNameMap.value[String(scope)] || scope;
+ };
+ const getApplyScopeTags = row => {
+ return parseApplyScope(row?.applyScope).map((scope, index) => ({
+ value: scope,
+ label: getApplyScopeLabel(scope),
+ }));
};
// 鑾峰彇绫诲瀷鏍囩绫诲瀷
@@ -569,20 +611,17 @@
};
return timeMap[efficiency] || "鏈煡";
};
- const emergencyPlanTypeOptions = computed(() => [
- {
- value: "棰勯槻鎬у簲鎬ラ妗�",
- label: "棰勯槻鎬у簲鎬ラ妗�",
- },
- {
- value: "搴旀�ュ鐞嗛妗�",
- label: "搴旀�ュ鐞嗛妗�",
- },
- {
- value: "鎭㈠鎬у簲鎬ラ妗�",
- label: "鎭㈠鎬у簲鎬ラ妗�",
- },
- ]);
+ const { proxy } = getCurrentInstance();
+ const { emergency_plan_type } = proxy.useDict("emergency_plan_type");
+ const emergencyPlanTypeOptions = computed(
+ () => emergency_plan_type?.value || []
+ );
+ const emergencyPlanTypeLabel = val => {
+ const item = emergencyPlanTypeOptions.value.find(
+ i => String(i.value) === String(val)
+ );
+ return item ? item.label : val;
+ };
// 鎻愪氦搴旀�ラ妗堣〃鍗�
const submitForm = async () => {
try {
@@ -601,12 +640,14 @@
}
}
- // 灏嗗簲鎬ュ缃楠よ浆鎹负JSON瀛楃涓�
- form.value.execSteps = JSON.stringify(execStepsList.value);
+ const submitData = {
+ ...form.value,
+ applyScope: form.value.applyScope.join(","),
+ execSteps: JSON.stringify(execStepsList.value),
+ };
if (dialogType.value === "add") {
// 鏂板搴旀�ラ妗�
- form.value.applyScope = form.value.applyScope.join(",");
- safeContingencyPlanAdd({ ...form.value })
+ safeContingencyPlanAdd(submitData)
.then(res => {
if (res.code == 200) {
ElMessage.success("娣诲姞鎴愬姛");
@@ -618,8 +659,7 @@
ElMessage.error(err.msg);
});
} else {
- form.value.applyScope = form.value.applyScope.join(",");
- safeContingencyPlanUpdate({ ...form.value })
+ safeContingencyPlanUpdate(submitData)
.then(res => {
if (res.code == 200) {
ElMessage.success("鏇存柊鎴愬姛");
@@ -664,8 +704,6 @@
};
// 瀵煎嚭
- const { proxy } = getCurrentInstance();
- const { knowledge_type } = proxy.useDict("knowledge_type");
// 瀛楀吀宸ュ叿
const knowledgeTypeOptions = computed(() => knowledge_type?.value || []);
@@ -741,6 +779,16 @@
gap: 8px;
}
+ .apply-scope-checkbox-group {
+ display: flex;
+ flex-wrap: wrap;
+ gap: 8px 16px;
+ }
+
+ .apply-scope-checkbox-group :deep(.el-checkbox) {
+ margin-right: 0;
+ }
+
.usage-stats {
margin-top: 16px;
}
@@ -766,45 +814,83 @@
.exec-steps-container {
border: 1px solid #e4e7ed;
- border-radius: 4px;
- padding: 15px;
+ border-radius: 8px;
+ padding: 20px;
background-color: #f9fafc;
+ margin-top: 10px;
}
.exec-step-item {
- margin-bottom: 10px;
- padding: 10px;
+ margin-bottom: 12px;
+ padding: 12px;
background-color: #ffffff;
border: 1px solid #e4e7ed;
- border-radius: 4px;
+ border-radius: 6px;
+ transition: all 0.3s ease;
+ }
+
+ .exec-step-item:hover {
+ box-shadow: 0 2px 12px 0 rgba(0, 0, 0, 0.1);
+ border-color: #c6e2ff;
}
.step-header {
display: flex;
align-items: flex-start;
flex-direction: column;
+ gap: 8px;
}
.exec-step-view {
- margin-bottom: 8px;
- padding-left: 20px;
+ margin-bottom: 16px;
+ padding-left: 24px;
position: relative;
+ line-height: 1.6;
+ }
+
+ .exec-step-view::before {
+ content: "";
+ position: absolute;
+ left: 10px;
+ top: 20px;
+ bottom: -16px;
+ width: 2px;
+ background-color: #eaeaea;
+ }
+
+ .exec-step-view:last-child::before {
+ display: none;
}
.step-number {
position: absolute;
left: 0;
+ top: 0;
+ width: 20px;
+ height: 20px;
+ line-height: 20px;
+ text-align: center;
font-weight: bold;
- color: #409eff;
+ color: #ffffff;
+ background-color: #409eff;
+ border-radius: 50%;
+ font-size: 12px;
+ z-index: 1;
}
.step-title {
- font-weight: bold;
- margin-right: 5px;
+ font-weight: 600;
+ margin-right: 8px;
+ color: #395a9c;
}
.no-data {
color: #909399;
font-style: italic;
+ text-align: center;
+ padding: 20px;
+ background-color: #f8f9fa;
+ border-radius: 4px;
+ margin-top: 10px;
}
</style>
--
Gitblit v1.9.3