From b07bf9830174d454a51fe913146657463158f8b6 Mon Sep 17 00:00:00 2001
From: gongchunyi <deslre0381@gmail.com>
Date: 星期四, 05 三月 2026 16:02:16 +0800
Subject: [PATCH] fix: 取出多余字段,人员检验修改为下拉框选择

---
 src/views/safeProduction/emergencyPlanReview/index.vue |  113 +++++++++++++++++++++++++++++++++++++-------------------
 1 files changed, 75 insertions(+), 38 deletions(-)

diff --git a/src/views/safeProduction/emergencyPlanReview/index.vue b/src/views/safeProduction/emergencyPlanReview/index.vue
index 07bf56e..eb68508 100644
--- a/src/views/safeProduction/emergencyPlanReview/index.vue
+++ b/src/views/safeProduction/emergencyPlanReview/index.vue
@@ -52,17 +52,18 @@
       <el-form ref="formRef"
                :model="form"
                :rules="rules"
-               label-width="120px">
+               label-position="top"
+               label-width="150px">
         <el-row :gutter="20">
           <el-col :span="12">
-            <el-form-item label="搴旀�ラ妗堢紪鐮�"
+            <el-form-item label="搴旀�ラ妗堢紪鐮侊細"
                           prop="planCode">
               <el-input v-model="form.planCode"
                         placeholder="璇疯緭鍏ュ簲鎬ラ妗堢紪鐮�" />
             </el-form-item>
           </el-col>
           <el-col :span="12">
-            <el-form-item label="搴旀�ラ妗堝悕绉�"
+            <el-form-item label="搴旀�ラ妗堝悕绉帮細"
                           prop="planName">
               <el-input v-model="form.planName"
                         placeholder="璇疯緭鍏ュ簲鎬ラ妗堝悕绉�" />
@@ -99,7 +100,7 @@
         </el-row>
         <el-row :gutter="20">
           <el-col :span="12">
-            <el-form-item label="棰勬绫诲瀷"
+            <el-form-item label="棰勬绫诲瀷锛�"
                           prop="planType">
               <el-select v-model="form.planType"
                          placeholder="璇烽�夋嫨棰勬绫诲瀷"
@@ -112,14 +113,14 @@
             </el-form-item>
           </el-col>
           <el-col :span="12">
-            <el-form-item label="澶囨敞"
+            <el-form-item label="澶囨敞锛�"
                           prop="remark">
               <el-input v-model="form.remark"
                         placeholder="璇疯緭鍏ュ娉�" />
             </el-form-item>
           </el-col>
         </el-row>
-        <el-form-item label="閫傜敤鑼冨洿"
+        <el-form-item label="閫傜敤鑼冨洿锛�"
                       prop="applyScope">
           <el-checkbox-group v-model="form.applyScope">
             <el-checkbox label="all">鍏ㄤ綋鍛樺伐</el-checkbox>
@@ -129,7 +130,7 @@
             <el-checkbox label="tech">鎶�鏈儴闂�</el-checkbox>
           </el-checkbox-group>
         </el-form-item>
-        <el-form-item label="搴旀�ュ缃楠�"
+        <el-form-item label="搴旀�ュ缃楠わ細"
                       prop="execSteps">
           <div class="exec-steps-container"
                style="width:100%">
@@ -164,9 +165,9 @@
       </el-form>
       <template #footer>
         <span class="dialog-footer">
-          <el-button @click="dialogVisible = false">鍙栨秷</el-button>
           <el-button type="primary"
                      @click="submitForm">纭畾</el-button>
+          <el-button @click="dialogVisible = false">鍙栨秷</el-button>
         </span>
       </template>
     </el-dialog>
@@ -192,7 +193,7 @@
             {{ currentKnowledge.coreResponsorUserName }}
           </el-descriptions-item>
           <el-descriptions-item label="棰勬绫诲瀷">
-            <el-tag type="warning"> {{ currentKnowledge.planType }}</el-tag>
+            <el-tag type="warning"> {{ emergencyPlanTypeLabel(currentKnowledge.planType) }}</el-tag>
           </el-descriptions-item>
           <el-descriptions-item label="澶囨敞">
             {{ currentKnowledge.remark }}
@@ -216,7 +217,7 @@
               <div v-for="(step, index) in JSON.parse(currentKnowledge.execSteps)"
                    :key="index"
                    class="exec-step-view">
-                <span class="step-number">{{ index + 1 }}.</span>
+                <!-- <span class="step-number">{{ index + 1 }}.</span> -->
                 <span class="step-title">{{ step.step }}锛�</span>
                 <span>{{ step.description }}</span>
               </div>
@@ -352,6 +353,9 @@
       label: "棰勬绫诲瀷",
       prop: "planType",
       showOverflowTooltip: true,
+      formatData: params => {
+        return emergencyPlanTypeLabel(params);
+      },
     },
     {
       label: "澶囨敞",
@@ -441,7 +445,7 @@
       .then(res => {
         tableLoading.value = false;
         tableData.value = res.data.records;
-        page.total = res.data.total;
+        page.value.total = res.data.total;
       })
       .catch(err => {
         tableLoading.value = false;
@@ -452,7 +456,7 @@
   const pagination = obj => {
     page.value.current = obj.page;
     page.value.size = obj.limit;
-    handleQuery();
+    getList();
   };
 
   // 閫夋嫨鍙樺寲澶勭悊
@@ -569,20 +573,17 @@
     };
     return timeMap[efficiency] || "鏈煡";
   };
-  const emergencyPlanTypeOptions = computed(() => [
-    {
-      value: "棰勯槻鎬у簲鎬ラ妗�",
-      label: "棰勯槻鎬у簲鎬ラ妗�",
-    },
-    {
-      value: "搴旀�ュ鐞嗛妗�",
-      label: "搴旀�ュ鐞嗛妗�",
-    },
-    {
-      value: "鎭㈠鎬у簲鎬ラ妗�",
-      label: "鎭㈠鎬у簲鎬ラ妗�",
-    },
-  ]);
+  const { proxy } = getCurrentInstance();
+  const { emergency_plan_type } = proxy.useDict("emergency_plan_type");
+  const emergencyPlanTypeOptions = computed(
+    () => emergency_plan_type?.value || []
+  );
+  const emergencyPlanTypeLabel = val => {
+    const item = emergencyPlanTypeOptions.value.find(
+      i => String(i.value) === String(val)
+    );
+    return item ? item.label : val;
+  };
   // 鎻愪氦搴旀�ラ妗堣〃鍗�
   const submitForm = async () => {
     try {
@@ -664,8 +665,6 @@
   };
 
   // 瀵煎嚭
-  const { proxy } = getCurrentInstance();
-  const { knowledge_type } = proxy.useDict("knowledge_type");
 
   // 瀛楀吀宸ュ叿
   const knowledgeTypeOptions = computed(() => knowledge_type?.value || []);
@@ -766,45 +765,83 @@
 
   .exec-steps-container {
     border: 1px solid #e4e7ed;
-    border-radius: 4px;
-    padding: 15px;
+    border-radius: 8px;
+    padding: 20px;
     background-color: #f9fafc;
+    margin-top: 10px;
   }
 
   .exec-step-item {
-    margin-bottom: 10px;
-    padding: 10px;
+    margin-bottom: 12px;
+    padding: 12px;
     background-color: #ffffff;
     border: 1px solid #e4e7ed;
-    border-radius: 4px;
+    border-radius: 6px;
+    transition: all 0.3s ease;
+  }
+
+  .exec-step-item:hover {
+    box-shadow: 0 2px 12px 0 rgba(0, 0, 0, 0.1);
+    border-color: #c6e2ff;
   }
 
   .step-header {
     display: flex;
     align-items: flex-start;
     flex-direction: column;
+    gap: 8px;
   }
 
   .exec-step-view {
-    margin-bottom: 8px;
-    padding-left: 20px;
+    margin-bottom: 16px;
+    padding-left: 24px;
     position: relative;
+    line-height: 1.6;
+  }
+
+  .exec-step-view::before {
+    content: "";
+    position: absolute;
+    left: 10px;
+    top: 20px;
+    bottom: -16px;
+    width: 2px;
+    background-color: #eaeaea;
+  }
+
+  .exec-step-view:last-child::before {
+    display: none;
   }
 
   .step-number {
     position: absolute;
     left: 0;
+    top: 0;
+    width: 20px;
+    height: 20px;
+    line-height: 20px;
+    text-align: center;
     font-weight: bold;
-    color: #409eff;
+    color: #ffffff;
+    background-color: #409eff;
+    border-radius: 50%;
+    font-size: 12px;
+    z-index: 1;
   }
 
   .step-title {
-    font-weight: bold;
-    margin-right: 5px;
+    font-weight: 600;
+    margin-right: 8px;
+    color: #395a9c;
   }
 
   .no-data {
     color: #909399;
     font-style: italic;
+    text-align: center;
+    padding: 20px;
+    background-color: #f8f9fa;
+    border-radius: 4px;
+    margin-top: 10px;
   }
 </style>

--
Gitblit v1.9.3