From 85f689b65f4fb915ffe6bb2e5e65d7a88dc22865 Mon Sep 17 00:00:00 2001
From: yuyu <1981343953@qq.com>
Date: 星期四, 10 八月 2023 16:59:25 +0800
Subject: [PATCH] Merge branch 'master' of http://192.168.110.209:9001/r/lims-before
---
src/views/rawMaterials/reportForInspection/forInspectionDetail.vue | 117 +++++++++++++++++++++++++++++++++++-----------------------
1 files changed, 71 insertions(+), 46 deletions(-)
diff --git a/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue b/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue
index a032887..28d5f75 100644
--- a/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue
+++ b/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue
@@ -26,14 +26,18 @@
</div> -->
</div>
<div class="message">
- <div class="message-item"><span><i class="el-icon-edit" />璇曢獙鏂规硶锛�</span></div>
+ <!-- <div class="message-item"><span><i class="el-icon-edit" />璇曢獙鏂规硶锛�</span></div> -->
<div class="message-item">
- <span><i class="el-icon-edit" />椤圭洰鍒嗙被锛�</span>
+ <span><i class="el-icon-edit" />妫�楠岀被鍨嬶細
+ <span v-if="inspectionDetail.type===0">鍘熸潗鏂欐楠�</span>
+ <span v-else-if="inspectionDetail.type===1">鍗婃垚鍝佹楠�</span>
+ <span v-else-if="inspectionDetail.type===2">鎴愬搧妫�楠�</span>
+ </span>
</div>
<div class="message-item">
- <span><i class="el-icon-edit" />鏇存柊浜猴細</span></div>
+ <span><i class="el-icon-edit" />鐧昏浜猴細<el-tag>{{ inspectionDetail.userName }}</el-tag></span></div>
<div class="message-item">
- <span><i class="el-icon-edit" />鏇存柊鏃堕棿锛�</span></div>
+ <span><i class="el-icon-edit" />鐧昏鏃ユ湡锛歿{ inspectionDetail.createTime }}</span></div>
</div>
</div>
<div class="card-main sample-list">
@@ -57,53 +61,58 @@
style="width: 100%"
>
<el-table-column
- prop="applicationOrdernumber"
- label="鐢宠鍗曞彿"
+ prop="materialNum"
+ label="鐗╂枡缂栧彿"
min-width="200"
/>
<el-table-column
- prop="typeofInspection"
- label="妫�楠岀被鍨�"
+ prop="materialName"
+ label="鐗╂枡鍚嶇О"
min-width="200"
/>
<el-table-column
prop="objectofInspection"
- label="妫�楠屽璞�"
+ label="鐗╂枡灞炴��"
min-width="200"
/>
<el-table-column
- prop="palceofObject"
- label="瀵硅薄浣嶇疆"
+ prop="materialBatch"
+ label="鎵规"
min-width="200"
/>
<el-table-column
- prop="name"
- label="瀵硅薄鍚嶇О"
+ prop="materialReelNumber"
+ label="鐩樺彿"
min-width="200"
/>
<el-table-column
- prop="date"
- label="鐧昏鏃ユ湡"
+ prop="specificationsSerialNumber"
+ label="鍨嬪彿"
min-width="200"
/>
<el-table-column
prop="registrant"
- label="鐧昏浜�"
+ label="瑙勬牸"
min-width="200"
/>
<el-table-column
prop="applicationTime"
- label="鐢宠鏃堕棿"
+ label="鍏ュ簱鏁伴噺"
+ min-width="200"
+ />
+ <el-table-column
+ prop="materialNum"
+ label="閫佹牱鏁伴噺"
min-width="200"
/>
<el-table-column
label="鎿嶄綔"
min-width="200"
- :fixed="true"
+ fixed="right"
>
<template slot-scope="scope">
- <el-button type="text" size="small" @click="handleClick(scope.row)">鏌ョ湅</el-button>
- <el-button type="text" size="small">浣滃簾</el-button>
+ <el-button type="text" size="small" @click="openChangeMaterial(scope.row)">缂栬緫</el-button>
+ <el-button type="text" size="small">鍒犻櫎</el-button>
</template>
</el-table-column>
</el-table>
@@ -165,7 +174,7 @@
</el-col>
</el-row>
</div>
- <el-row gutter="100" :style="{marginTop:'24px'}">
+ <el-row :gutter="100" :style="{marginTop:'24px'}">
<el-col :span="12">
<el-form-item label="鎵规">
<el-input placeholder="" />
@@ -177,7 +186,7 @@
</el-form-item>
</el-col>
</el-row>
- <el-row gutter="100">
+ <el-row :gutter="100">
<el-col :span="12">
<el-form-item label="鐩樺彿">
<el-input placeholder="" />
@@ -189,7 +198,7 @@
</el-form-item>
</el-col>
</el-row>
- <el-row gutter="100">
+ <el-row :gutter="100">
<el-col :span="12">
<el-form-item label="瑙勬牸/鍨嬪彿鍚嶇О">
<el-input placeholder="" />
@@ -201,7 +210,7 @@
</el-form-item>
</el-col>
</el-row>
- <el-row gutter="100">
+ <el-row :gutter="100">
<el-col :span="12">
<el-form-item label="鐢熶骇鎸囦护鍙�">
<el-input placeholder="" />
@@ -213,14 +222,14 @@
</el-form-item>
</el-col>
</el-row>
- <el-row gutter="100">
+ <el-row :gutter="100">
<el-col :span="12">
<el-form-item label="鐢靛帇绛夌骇">
<el-input placeholder="" />
</el-form-item>
</el-col>
</el-row>
- <el-row gutter="100" :style="{flex:'1'}">
+ <el-row :gutter="100" :style="{flex:'1'}">
<el-col :span="24">
<el-form-item label="澶囨敞">
<el-input
@@ -232,7 +241,7 @@
</el-col>
</el-row>
<el-form-item>
- <el-button type="primary" @click="onSubmit">绔嬪嵆鍒涘缓</el-button>
+ <el-button type="primary">绔嬪嵆鍒涘缓</el-button>
<el-button>鍙栨秷</el-button>
</el-form-item>
</el-form>
@@ -243,7 +252,7 @@
<!-- Left side tree structure -->
<div class="tree-container">
<span class="all"> 鍏ㄩ儴</span>
- <el-tree :data="treeData" @node-click="handleNodeClick" ></el-tree>
+ <el-tree :data="treeData" />
</div>
<!-- Right side material list -->
<div class="table-container">
@@ -252,38 +261,40 @@
:data="selectedNodeMaterials"
style="width: 100%"
highlight-current-row
- @row-click="handleSelectionChange"
:header-row-class-name="headerBg"
- >
+ @row-click="handleSelectionChange"
+ >
<el-table-column
label="鐗╂枡缂栧彿"
- prop="number">
+ prop="number"
+ >
<template slot-scope="scope">
- <el-radio v-model="radioSelected" :label="scope.row.number" @change.native='handleSelectionChange(scope.row)'> </el-radio>
+ <el-radio v-model="radioSelected" :label="scope.row.number" @change.native="handleSelectionChange(scope.row)"> </el-radio>
</template>
</el-table-column>
- <el-table-column prop="name" label="鐗╂枡鍚嶇О"></el-table-column>
- </el-table>
- <el-pagination
- @size-change="handleSizeChange"
- @current-change="handleCurrentChange"
- :current-page="pageParams.pageNo"
- :page-sizes="[10, 20, 30, 40]"
- :page-size="pageParams.pageSize"
- :total="pageParams.total"
- layout="total, sizes, prev, pager, next, jumper"
- />
- </div>
+ <el-table-column prop="name" label="鐗╂枡鍚嶇О" />
+ </el-table>
+ <el-pagination
+ :current-page="pageParams.pageNo"
+ :page-sizes="[10, 20, 30, 40]"
+ :page-size="pageParams.pageSize"
+ :total="pageParams.total"
+ layout="total, sizes, prev, pager, next, jumper"
+ @size-change="handleSizeChange"
+ @current-change="handleCurrentChange"
+ />
+ </div>
</div>
<div slot="footer" class="dialog-footer">
<el-button @click="chooseMaterialVisible = false">鍙� 娑�</el-button>
- <el-button type="primary" >纭畾閫夋嫨</el-button>
+ <el-button type="primary">纭畾閫夋嫨</el-button>
</div>
</el-dialog>
</div>
</template>
<script>
+import { getInspectionMaterialListById } from '@/api/rawMaterials/reportForInspection'
export default {
data() {
return {
@@ -337,10 +348,24 @@
name: '娴嬭瘯鏁版嵁2'
}],
radioSelected: null,
- multipleSelection: ''
+ multipleSelection: '',
+ inspectionDetail: {}
}
},
+ created() {
+ // console.log(this.$route.query) 浼犻�掔殑鐢宠鍗曞璞¤鎯�
+ this.inspectionDetail = JSON.parse(this.$route.query.inspectionDetail)
+ this.getMaterialList()
+ },
methods: {
+ openChangeMaterial(row) {
+ console.log(row)
+ },
+ async getMaterialList() {
+ const res = await getInspectionMaterialListById({ inspectionId: this.inspectionDetail.id })
+ // console.log(res)
+ this.sampleTable = res.data
+ },
handleSelectionChange(val) {
console.log(val)
this.radioSelected = val.number // 閫変腑琛岀殑number
--
Gitblit v1.9.3