From c977c9fb967a080ca56ac46b1f17ce2c57f2122e Mon Sep 17 00:00:00 2001
From: Fixiaobai <fixiaobai@163.com>
Date: 星期四, 10 八月 2023 17:53:53 +0800
Subject: [PATCH] 	new file:   src/api/urlEnum/satisfactionSurveys.js 	modified:   src/views/CNAS/satisfactionSurveys/index.vue

---
 src/views/rawMaterials/reportForInspection/forInspectionDetail.vue |  117 +++++++++++++++++++++++++++++++++++-----------------------
 1 files changed, 71 insertions(+), 46 deletions(-)

diff --git a/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue b/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue
index a032887..28d5f75 100644
--- a/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue
+++ b/src/views/rawMaterials/reportForInspection/forInspectionDetail.vue
@@ -26,14 +26,18 @@
             </div> -->
         </div>
         <div class="message">
-          <div class="message-item"><span><i class="el-icon-edit" />璇曢獙鏂规硶锛�</span></div>
+          <!-- <div class="message-item"><span><i class="el-icon-edit" />璇曢獙鏂规硶锛�</span></div> -->
           <div class="message-item">
-            <span><i class="el-icon-edit" />椤圭洰鍒嗙被锛�</span>
+            <span><i class="el-icon-edit" />妫�楠岀被鍨嬶細
+              <span v-if="inspectionDetail.type===0">鍘熸潗鏂欐楠�</span>
+              <span v-else-if="inspectionDetail.type===1">鍗婃垚鍝佹楠�</span>
+              <span v-else-if="inspectionDetail.type===2">鎴愬搧妫�楠�</span>
+            </span>
           </div>
           <div class="message-item">
-            <span><i class="el-icon-edit" />鏇存柊浜猴細</span></div>
+            <span><i class="el-icon-edit" />鐧昏浜猴細<el-tag>{{ inspectionDetail.userName }}</el-tag></span></div>
           <div class="message-item">
-            <span><i class="el-icon-edit" />鏇存柊鏃堕棿锛�</span></div>
+            <span><i class="el-icon-edit" />鐧昏鏃ユ湡锛歿{ inspectionDetail.createTime }}</span></div>
         </div>
       </div>
       <div class="card-main sample-list">
@@ -57,53 +61,58 @@
             style="width: 100%"
           >
             <el-table-column
-              prop="applicationOrdernumber"
-              label="鐢宠鍗曞彿"
+              prop="materialNum"
+              label="鐗╂枡缂栧彿"
               min-width="200"
             />
             <el-table-column
-              prop="typeofInspection"
-              label="妫�楠岀被鍨�"
+              prop="materialName"
+              label="鐗╂枡鍚嶇О"
               min-width="200"
             />
             <el-table-column
               prop="objectofInspection"
-              label="妫�楠屽璞�"
+              label="鐗╂枡灞炴��"
               min-width="200"
             />
             <el-table-column
-              prop="palceofObject"
-              label="瀵硅薄浣嶇疆"
+              prop="materialBatch"
+              label="鎵规"
               min-width="200"
             />
             <el-table-column
-              prop="name"
-              label="瀵硅薄鍚嶇О"
+              prop="materialReelNumber"
+              label="鐩樺彿"
               min-width="200"
             />
             <el-table-column
-              prop="date"
-              label="鐧昏鏃ユ湡"
+              prop="specificationsSerialNumber"
+              label="鍨嬪彿"
               min-width="200"
             />
             <el-table-column
               prop="registrant"
-              label="鐧昏浜�"
+              label="瑙勬牸"
               min-width="200"
             />
             <el-table-column
               prop="applicationTime"
-              label="鐢宠鏃堕棿"
+              label="鍏ュ簱鏁伴噺"
+              min-width="200"
+            />
+            <el-table-column
+              prop="materialNum"
+              label="閫佹牱鏁伴噺"
               min-width="200"
             />
             <el-table-column
               label="鎿嶄綔"
               min-width="200"
-              :fixed="true"
+              fixed="right"
             >
               <template slot-scope="scope">
-                <el-button type="text" size="small" @click="handleClick(scope.row)">鏌ョ湅</el-button>
-                <el-button type="text" size="small">浣滃簾</el-button>
+                <el-button type="text" size="small" @click="openChangeMaterial(scope.row)">缂栬緫</el-button>
+                <el-button type="text" size="small">鍒犻櫎</el-button>
               </template>
             </el-table-column>
           </el-table>
@@ -165,7 +174,7 @@
               </el-col>
             </el-row>
           </div>
-          <el-row gutter="100" :style="{marginTop:'24px'}">
+          <el-row :gutter="100" :style="{marginTop:'24px'}">
             <el-col :span="12">
               <el-form-item label="鎵规">
                 <el-input placeholder="" />
@@ -177,7 +186,7 @@
               </el-form-item>
             </el-col>
           </el-row>
-          <el-row gutter="100">
+          <el-row :gutter="100">
             <el-col :span="12">
               <el-form-item label="鐩樺彿">
                 <el-input placeholder="" />
@@ -189,7 +198,7 @@
               </el-form-item>
             </el-col>
           </el-row>
-          <el-row gutter="100">
+          <el-row :gutter="100">
             <el-col :span="12">
               <el-form-item label="瑙勬牸/鍨嬪彿鍚嶇О">
                 <el-input placeholder="" />
@@ -201,7 +210,7 @@
               </el-form-item>
             </el-col>
           </el-row>
-          <el-row gutter="100">
+          <el-row :gutter="100">
             <el-col :span="12">
               <el-form-item label="鐢熶骇鎸囦护鍙�">
                 <el-input placeholder="" />
@@ -213,14 +222,14 @@
               </el-form-item>
             </el-col>
           </el-row>
-          <el-row gutter="100">
+          <el-row :gutter="100">
             <el-col :span="12">
               <el-form-item label="鐢靛帇绛夌骇">
                 <el-input placeholder="" />
               </el-form-item>
             </el-col>
           </el-row>
-          <el-row gutter="100" :style="{flex:'1'}">
+          <el-row :gutter="100" :style="{flex:'1'}">
             <el-col :span="24">
               <el-form-item label="澶囨敞">
                 <el-input
@@ -232,7 +241,7 @@
             </el-col>
           </el-row>
           <el-form-item>
-            <el-button type="primary" @click="onSubmit">绔嬪嵆鍒涘缓</el-button>
+            <el-button type="primary">绔嬪嵆鍒涘缓</el-button>
             <el-button>鍙栨秷</el-button>
           </el-form-item>
         </el-form>
@@ -243,7 +252,7 @@
         <!-- Left side tree structure -->
         <div class="tree-container">
           <span class="all"> 鍏ㄩ儴</span>
-          <el-tree :data="treeData" @node-click="handleNodeClick" ></el-tree>
+          <el-tree :data="treeData" />
         </div>
         <!-- Right side material list -->
         <div class="table-container">
@@ -252,38 +261,40 @@
             :data="selectedNodeMaterials"
             style="width: 100%"
             highlight-current-row
-            @row-click="handleSelectionChange"
             :header-row-class-name="headerBg"
-            >
+            @row-click="handleSelectionChange"
+          >
             <el-table-column
               label="鐗╂枡缂栧彿"
-              prop="number">
+              prop="number"
+            >
               <template slot-scope="scope">
-                <el-radio v-model="radioSelected" :label="scope.row.number" @change.native='handleSelectionChange(scope.row)'>&nbsp;  </el-radio>
+                <el-radio v-model="radioSelected" :label="scope.row.number" @change.native="handleSelectionChange(scope.row)">&nbsp;  </el-radio>
               </template>
             </el-table-column>
-            <el-table-column prop="name" label="鐗╂枡鍚嶇О"></el-table-column>
-        </el-table>
-        <el-pagination
-          @size-change="handleSizeChange"
-          @current-change="handleCurrentChange"
-          :current-page="pageParams.pageNo"
-          :page-sizes="[10, 20, 30, 40]"
-          :page-size="pageParams.pageSize"
-          :total="pageParams.total"
-          layout="total, sizes, prev, pager, next, jumper"
-        />
-      </div>
+            <el-table-column prop="name" label="鐗╂枡鍚嶇О" />
+          </el-table>
+          <el-pagination
+            :current-page="pageParams.pageNo"
+            :page-sizes="[10, 20, 30, 40]"
+            :page-size="pageParams.pageSize"
+            :total="pageParams.total"
+            layout="total, sizes, prev, pager, next, jumper"
+            @size-change="handleSizeChange"
+            @current-change="handleCurrentChange"
+          />
+        </div>
       </div>
       <div slot="footer" class="dialog-footer">
         <el-button @click="chooseMaterialVisible = false">鍙� 娑�</el-button>
-        <el-button type="primary" >纭畾閫夋嫨</el-button>
+        <el-button type="primary">纭畾閫夋嫨</el-button>
       </div>
     </el-dialog>
   </div>
 </template>
 
 <script>
+import { getInspectionMaterialListById } from '@/api/rawMaterials/reportForInspection'
 export default {
   data() {
     return {
@@ -337,10 +348,24 @@
           name: '娴嬭瘯鏁版嵁2'
         }],
       radioSelected: null,
-      multipleSelection: ''
+      multipleSelection: '',
+      inspectionDetail: {}
     }
   },
+  created() {
+    // console.log(this.$route.query) 浼犻�掔殑鐢宠鍗曞璞¤鎯�
+    this.inspectionDetail = JSON.parse(this.$route.query.inspectionDetail)
+    this.getMaterialList()
+  },
   methods: {
+    openChangeMaterial(row) {
+      console.log(row)
+    },
+    async getMaterialList() {
+      const res = await getInspectionMaterialListById({ inspectionId: this.inspectionDetail.id })
+      // console.log(res)
+      this.sampleTable = res.data
+    },
     handleSelectionChange(val) {
       console.log(val)
       this.radioSelected = val.number // 閫変腑琛岀殑number

--
Gitblit v1.9.3